Bio Medical Waste

Sanmit Infra Limited took a step for safeguarding the environment and the ecosystem. This is to avoid the spread of hazardous infection from healthy lives and families by eliminating its spread during transportation from the general public.

Think About This

Disinfection of Biomedical Waste at the Point of Source is the only solution to Eradicate Bacteria, Viruses, Pathogens and Microbes from Health Care Facilities and the Environment thus saving life of all the front warrior such as Doctors, Health Care Staff, Patients and Visitors.

Bring Awareness

An Ultra Violet Radiation (UVR) & Microwave Dual Disinfection System

An Ultra Violet Radiation (UVR) and Microwave Dual Disinfection System in the temperature maintenance aone will completely eliminate pathogens, bacteria, Microbes and Viruses in Hazardous Bio Medical Waste (HBMW) turning it to Municipal refuse or can be supplied for recycling after sorting.

Metal, Glass/Broken Glass, all kind of face masks including N95 Mask, gloves, metal apparatus, surgical instrument, linen, bed sheet, Personal Protection Equipment (PPE) Kits can be irradiated through Ultra Violet Germicidal Irradiation (UVGI) Process, killing all the pathogens, bacteria, Microbes and Viruses. The efficacy test done by HAFFKINE INSTUTITE, MUMBAI.

Features

Biomedical Waste Disposal System An Ultra Violet Radiation (UVR) And Microwave Dual Disinfection System Features

Eco Friendly

User Friendly

Efficient

No Chemicals

Safe

Non Infection End Product

Compact

Fast

Threat / Store / Discard

Safety Door Lock

The Treatments

THE TREATMENT SECTION COMPRISE OF :

1. ULTRA VIOLET GERMICIDAL IRRADIATION (UVGI) PROCESS.

2. HIGH FREQUENCY HIGH TEMPERATURE DISINFECTION (HFHTD)

3. PROCESS TEMPERATURE MAINTENANCE (TM) PROCESS.

Waste Which Can be pre Treated

Yellow

(C) Solid Waste Trims Contaminated with blood. Body fluids like dressing, plaster cast cotton swab and bags containing residual or discarded blood and blood Components.

Red

Plastic Waste such as tubing, bottles, intravenous tubes and sets, catheters, urine bags, syringes (without needles and fixed needle syringes) and vacutainers (with their needles cut) and gloves.

White

Sharp Waste including metals like Needles, Syringes with fixed needles, needles from needle tip cutter or burner, scalpels, blades, etc.

Blue

Broken or discarded and contaminated glass including medicine vials and ampoules except
those contaminated with cytotoxic wastes and metallic body implants.

Our machines

SAN-MIT-20

  • Nominal capacity of disinfection system in liters per cycle : 20
  • Duration of one disinfection cycle in minutes : 45 – 50
  • Dimensions in mm x mm x mm (H”W”D) :  1200 x 1085 x 695
  • Material of construction of external body : Stainless Steel (SS) 304 grade External Body for Ultra Violet Radiation (UVR) and Microwave Applicator with sealable Leak Proof Front Cover of the unit.
  • Inner Ultraviolet Radiation chamber construction : Specially Designed Rectangular Chamber Made of SS 304 Grade Stainless Steel.
  • Ultra Violet Radiation (UVR) : Wavelength 200 – 280 nm.
  • Microwave output power in kw : 1
  • No. of Magnetrons : 1
  • Bluetooth : Optional
  • QR Code Printing : Optinal
  • Embedded System Based HMI : Yes
  • IOT (Internet of Things) : Yes
  • Shredder : Optional
  • Warranty in years : 1/2/3/5

SAN-MIT-50

  • Nominal capacity of disinfection system in liters per cycle : 50
  • Duration of one disinfection cycle in minutes : 45 – 50
  • Dimensions in mm x mm x mm (H”W”D) :  1670 x 1085 x 695
  • Material of construction of external body : Stainless Steel (SS) 304 grade External Body for Ultra Violet Radiation (UVR) and Microwave Applicator with sealable Leak Proof Front Cover of the unit.
  • Inner Ultraviolet Radiation chamber construction : Specially Designed Rectangular Chamber Made of SS 304 Grade Stainless Steel.
  • Ultra Violet Radiation (UVR) : Wavelength 200 – 280 nm.
  • Microwave output power in kw : 2
  • No. of Magnetrons : 2
  • Bluetooth : Optional
  • QR Code Printing : Optinal
  • Embedded System Based HMI : Yes
  • IOT (Internet of Things) : Yes
  • Shredder : Optional
  • Warranty in years : 1/2/3/5

SAN-MIT-50

  • Nominal capacity of disinfection system in liters per cycle : 50
  • Duration of one disinfection cycle in minutes : 45 – 50
  • Dimensions in mm x mm x mm (H”W”D) :  1670 x 1085 x 695
  • Material of construction of external body : Stainless Steel (SS) 304 grade External Body for Ultra Violet Radiation (UVR) and Microwave Applicator with sealable Leak Proof Front Cover of the unit.
  • Inner Ultraviolet Radiation chamber construction : Specially Designed Rectangular Chamber Made of SS 304 Grade Stainless Steel.
  • Ultra Violet Radiation (UVR) : Wavelength 200 – 280 nm.
  • Microwave output power in kw : 2
  • No. of Magnetrons : 2
  • Bluetooth : Optional
  • QR Code Printing : Optinal
  • Embedded System Based HMI : Yes
  • IOT (Internet of Things) : Yes
  • Shredder : Optional
  • Warranty in years : 1/2/3/5

SAN-MIT-75

  • Nominal capacity of disinfection system in liters per cycle : 75
  • Duration of one disinfection cycle in minutes : 45 – 50
  • Dimensions in mm x mm x mm (H”W”D) :  1870 x 1085 x 695
  • Material of construction of external body : Stainless Steel (SS) 304 grade External Body for Ultra Violet Radiation (UVR) and Microwave Applicator with sealable Leak Proof Front Cover of the unit.
  • Inner Ultraviolet Radiation chamber construction : Specially Designed Rectangular Chamber Made of SS 304 Grade Stainless Steel.
  • Ultra Violet Radiation (UVR) : Wavelength 200 – 280 nm.
  • Microwave output power in kw : 3
  • No. of Magnetrons : 2
  • Bluetooth : Optional
  • QR Code Printing : Optinal
  • Embedded System Based HMI : Yes
  • IOT (Internet of Things) : Yes
  • Shredder : Optional
  • Warranty in years : 1/2/3/5

Output Form

Emission Discharge

Cross Contamination

Chemicals

0%

Running Cost

Misuse of Technology

Maintenance

What we Do

Individual & Corporates Accounting Services The Treatment Section Comprises Of

The Rules apply to all persons who generate, collect, receive, store, transport, treat, dispose or handle bio-medical waste in any form.
Rules under the Environment (Protection) Act, 1986.
I draft – 1995 | II draft – 1997
Final rules notified on 27th July 1998, Bio Medical Waste (Management & Handling) Rules, 1998.
Latest Amendments – 2003

New Rules Notified on 28.3.16, Bio medical Waste Management Rules,2016

  • As per Biomedical Waste Management (BMWM) Rules 2016, Medical waste needs to be “PRE-TREATED” at the point of generation before being disposing off.
  • The “PRE-TREATMENT” of this Highly Infectious Waste at the point of generation/first source (i.e. GOVT Hospital/Private Hospital/Nursing Home/Dispensaries. Primary Health
    Centers/Medical colleges and research centers/paramedical services/ Veterinary colleges/animal research centers. Blood banks/mortuaries/autopsy centers/ Biotechnology Institutions) can be successfully done by “MICROWAVE DISINFECTION SYSTEM” whereby saves Doctors, nurses, hospital, health care staff and patients at the first source from infections and thereby eliminating its spread during transportation of this BIOMEDICAL WASTE for general public.

Embedded System With HMI

An Embedded Control System, based Human-Machine Interface (HMI). programmed for resource-optimized operations, with innovative and adaptive algorithm as herein described, interfaced to the said AN ULTRA VIOLET RADIATION (UVR) AND MICROWAVE DUAL DISINFECTION SYSTEM to ensure Total Automatic Disinfection Cycle with Minimum Human Intervention

The embedded controller performs monitoring and control operations of various subsystems for same and efficient operation.

The embedded system can operate this disinfection system in three modes:

1. Ultra Violet mode

2. Microwave mode

3. Hybrid mode

Thoughts On Prevention Of Pandemic

” True Prevention is not waiting for bad things to happen, it’s preventing things from happening in the first place.”

” Intellectuals solve problems, geniuses prevent them.”

” Diseases can rarely be eliminated through early diagnosis or good treatment, but Disinfection at the Point of Generation can eliminate disease.”

Disinfection means Prevention and Prevention is the daughter of intelligence.”

” One of the best aspects of health care reform is it starts to emphasize to Disinfect the Biomedical Hazardous Waste at the Point Of Generation.”

Disinfection of Bio Medical Waste must become the Prime Goal of every Health Care Facilities (HCF).”